USB Dongles Available

Shows the number of USB dongles recognized by the analyzer.

USB dongles available - figure 153

Figure 215 – USB Dongles Available

In case of dongles that use virtual COM ports (e.g. Dizic, STMicroelectronics, Freescale), a list of the COM ports will follow the number of available dongles.

Only dongles that are configured with the appropriate firmware, and that are not used by another application will be recognized by the Perytons™ Protocol Analyzer and counted.

Although not recommended to do so, if dongles are inserted or removed while the capture form is opened, the Refresh Dongles button should be clicked in order to update the number and type of available dongles.
Note: Updating dongles may take about 1sec per each dongle. So in case of full capacity, refresh dongles may take several seconds.

Refresh Donlges - Figure 154

Figure 216 – Refresh Dongles

When pressing the Refresh Dongles button, the analyzer first disconnects the existing dongles (the progress is shown in the status bar):

DissconnectingDongles

Figure 217 – Disconnecting existing dongles in progress

Then it searches for available dongles:

ConnectingDongles

Figure 218 – Connecting dongles in progress

Note: For dongles that communicate with the analyzer over COM port the analyzer sends reset command to all potential COM ports. In cases, where other devices are connected to the PC over COM ports, these devices may reply badly to the analyzer test message.
For such cases the user may define manually the COM ports that the analyzer will use (or exclude the ones the analyzer shouldn’t use). See
‎19.1.

Given the number of available USB dongles, the user may choose the channels he would like to capture data from, by checking the boxes with the relevant channel number.

ChoosingChannels

Figure 219 – Choosing channels to capture Data from

If the number of checked boxes exceeds the number of available dongles a warning icon will appear, and the start button will be disabled:

MoreChannelsThanDongles

Figure 220 – Trying to capture more Channels than Dongles available, notice

Note: Inserting or removing USB dongles while data capture is in progress is not recommended. To change the number of dongles, stop the current capture, insert or remove dongles, wait for the operating system to detect/install the new dongles (this make take a few seconds), and only then refresh the number of dongles and start a new capture.
If the number of dongles displayed doesn’t match the actual number of dongles installed, and Refresh Dongles doesn’t help, the user needs to take out the dongles and insert them again. If a USB hub is used, the USB cable between the HUB and the PC should be disconnected, the HUB power cord taken out and then the power and USB cable reconnected back (in this order). In any case it is required to wait a few seconds for the operating system to detect the new dongles before using the Capture form "Refresh Dongles" button.