Holds settings required when using the TI CC1111 front-end for receiving packets from not-standard Sub 1 GHz networks (see also VI.2).
Other registers as well as some bits of these registers are set by the analyzer according to the parameters entered in the capture form (e.g. frequency, receiver bandwidth, etc.):
Figure 306 – Preferences, TI CC1111
Note: It is strongly recommended to consult with the CC111x documentation for getting familiar with the required RF register settings and how they affect the radio interface – see http://www.ti.com/lit/ds/symlink/cc1110f32.pdf.
• SYNC1:
Single byte (hex) setting to load to the SYNC1 register
• SYNC0:
Single byte (hex) setting to load to the SYNC0 register
• PKTCTRL1:
Single byte (hex) setting to load to the PKTCTRL1 register
• PKTCTRL0:
Single byte (hex) setting to load to the PKTCTRL0 register
• CHANNR:
Single byte (hex) setting to load to the CHANNR register
• SYNC_MODE:
Single byte (hex) setting to load to the SYNC_MODE register
• FEC_EN:
When selected, enable using Forward Error Correction
• NUM_PREAMBLE:
Single byte (hex) setting to load to the NUM_PREAMBLE register
• DASH7 Enhanced Settings:
When selected, set 433 MHz protocols (such as DASH7) related parameters manually for DASH7 capture sessions (see VI.3).
• Channel Spacing:
Value in kHz to load to the channel spacing registers