The user can use the TI CC1111 for capturing non 802.15.4 standard data in the Sub 1 GHz band.
See also par. IV.19.13.
In such case the following capture form is used:
Figure 415 – Data Capture in SubGHz networks form
Before starting a data capture the user should set the requested parameters such as:
'Freq [KHz] - required center channel frequency
'Deviation [KHz] - required deviation
'Bit Rate [Hz]' – used data transmission bit rate
'RX BW [KHz]' – used reception band-width
The required modulation type should be chosen from the drop-down list:
Figure 416 – TI CC 1111 Sub 1 GHz drop-down list