The following table summarizes the ZigBee Clusters currently supported by the Perytons™ Protocol Analyzer:
Functional Domain |
Cluster Name |
Cluster ID |
Comments |
General |
Basic |
0x0000 |
|
General |
Power configuration |
0x0001 |
|
General |
Device temperature configuration |
0x0002 |
|
General |
Identify |
0x0003 |
|
General |
Groups |
0x0004 |
|
General |
Scenes |
0x0005 |
|
General |
OnOff |
0x0006 |
|
General |
On/Off Switch Configuration |
0x0007 |
|
General |
LevelControl |
0x0008 |
|
General |
Alarms |
0x0009 |
|
General |
time |
0x000A |
|
General |
RSSI Location |
0x000b |
|
General |
Analog Input (Basic) |
0x000c |
|
General |
Analog Output (Basic) |
0x000d |
|
General |
Analog Value (Basic) |
0x000e |
|
General |
Binary Input (Basic) |
0x000f |
|
General |
Binary Output (Basic) |
0x0010 |
|
General |
Binary Value (Basic) |
0x0011 |
|
General |
Multistate Input (Basic) |
0x0012 |
|
General |
Multistate Output (Basic) |
0x0013 |
|
General |
Multistate Value (Basic) |
0x0014 |
|
General |
Commissioning |
0x0015 |
|
General |
Partition |
0x0016 |
|
General |
AlphaSecureKeyEstablishment |
0x0017 |
|
General |
Alpha-Secure Access Control (ASAC) |
0x0018 |
|
General |
Over The Air Updates |
0x0019 |
|
|
Power Profile |
0x001A |
|
|
E@H Appliance Control |
0x001B |
|
|
Poll control |
0x0020 |
|
|
GP Proxy |
0x0021 |
|
|
Mobile Device Configuration |
0x0022 |
|
|
Neighbor Cleaning |
0x0023 |
|
|
Nearest Gateway |
0x0024 |
|
|
Keep-Alive |
0x0025 |
|
Closures |
Shade Configuration |
0x0100 |
|
Closures |
Door Lock |
0x0101 |
|
Closures |
Window Covering |
0x0102 |
|
HVAC |
Pump Configuration and Control |
0x0200 |
|
HVAC |
Thermostat |
0x0201 |
|
HVAC |
Fan Control |
0x0202 |
|
HVAC |
Dehumidification Control |
0x0203 |
|
HVAC |
Thermostat User Interface Configuration |
0x0204 |
|
Lighting |
Color Control |
0x0300 |
|
Lighting |
Ballast Configuration |
0x0301 |
|
Measurement & Sensing |
I luminance Measurement |
0x0400 |
|
Measurement & Sensing |
I luminance Level Sensing |
0x0401 |
|
Measurement & Sensing |
Temperature Measurement |
0x0402 |
|
Measurement & Sensing |
Pressure Measurement |
0x0403 |
|
Measurement & Sensing |
Flow Measurement |
0x0404 |
|
Measurement & Sensing |
Relative Humidity Measurement |
0x0405 |
|
Measurement & Sensing |
Occupancy sensing |
0x0406 |
|
Security and Safety |
IAS Zone |
0x0500 |
|
Security and Safety |
IAS ACE |
0x0501 |
|
Security and Safety |
IAS WD |
0x0502 |
|
Protocol Interfaces |
Generic Tunnel |
0x0600 |
|
Protocol Interfaces |
BACnet Protocol Tunnel |
0x0601 |
|
Protocol Interfaces |
Analog Input (BACnet Regular) |
0x0602 |
|
Protocol Interfaces |
Analog Input (BACnet Extended) |
0x0603 |
|
Protocol Interfaces |
Analog Output (BACnet Regular) |
0x0604 |
|
Protocol Interfaces |
Analog Output (BACnet Extended) |
0x0605 |
|
Protocol Interfaces |
Analog Value (BACnet Regular) |
0x0606 |
|
Protocol Interfaces |
Analog Value (BACnet Extended) |
0x0607 |
|
Protocol Interfaces |
Binary Input (BACnet Regular) |
0x0608 |
|
Protocol Interfaces |
Binary Input (BACnet Extended) |
0x0609 |
|
Protocol Interfaces |
Binary Output (BACnet Regular) |
0x060a |
|
Protocol Interfaces |
Binary Output (BACnet Extended) |
0x060b |
|
Protocol Interfaces |
Binary Value (BACnet Regular) |
0x060c |
|
Protocol Interfaces |
Binary Value (BACnet Extended) |
0x060d |
|
Protocol Interfaces |
Multistate Input |
0x060e |
|
Protocol Interfaces |
Multistate Input (BACnet Extended) |
0x060f |
|
Protocol Interfaces |
Multistate Output (BACnet Regular) |
0x0610 |
|
Protocol Interfaces |
Multistate Output (BACnet Extended) |
0x0611 |
|
Protocol Interfaces |
Multistate Value (BACnet Regular) |
0x0612 |
|
Protocol Interfaces |
Multistate Value(BACnet Extended) |
0x0613 |
|
Protocol Interfaces |
11073 Protocol Tunnel |
0x0614 |
|
Protocol Interfaces |
7816 Protocol Tunnel |
0x0615 |
|
|
Retail Tunneling |
0x0617 |
|
Smart Energy |
Price |
0x0700 |
|
Smart Energy |
Demand Response and Load Control |
0x0701 |
|
Smart Energy |
Simple Metering |
0x0702 |
|
Smart Energy |
Messaging |
0x0703 |
|
Smart Energy |
Smart Energy Tunneling (Complex Metering) |
0x0704 |
|
Smart Energy |
Pre-Payment |
0x0705 |
|
Smart Energy UK extension |
TOU Calendar |
TBD |
|
Smart Energy UK extension |
Calendar |
0x0707 |
|
Smart Energy UK extension |
Device Management |
0x0708 |
|
General |
KeyEstablishment |
0x0800 |
|
Telecom Services |
Information |
0x0900 |
|
Telecom Services |
Data Sharing |
0x0901 |
|
Telecom Services |
Gaming |
0x0902 |
|
Telecom Services |
Data Rate Control |
0x0903 |
|
Telecom Services |
Voice Over ZigBee |
0x0904 |
|
Telecom Services |
Chatting |
0x0905 |
|
Telecom Services |
Payment |
0x0A01 |
|
Telecom Services |
TA-billing |
0x0A02 |
|
Home Automation |
E@H Meter identification |
0x0B01 |
|
Home Automation |
E@H Appliance Events And Alerts |
0x0B02 |
|
Home Automation |
E@H Appliance Statistics |
0x0B03 |
|
Home Automation |
Electrical Measurement |
0x0B04 |
|
Home Automation |
Diagnostics |
0x0B05 |
|
Telecom Services |
Commissioning |
0x1000 |
|
Table 6 – Supported ZigBee Clusters